카테고리 보관물: Fluorescence

AcquCAM Pro/G3

AcquCAM Pro/G3

Down load Catalog _ AcquCAM PRO/G3

AcquCAM Pro/G3

 AcquCAM Pro/G3 USB 3.0 camera is the perfect solution for many bio, industrial, medical applications. Utilizing the very sensitive color CCD sensors, these cameras feature a specialization of fluorescence observations. With up to 30 fps and a trigger delay of less than 5 micro seconds.

  • 1.2 Mega pixel CCD camera
  • Color, Progressive scan
  • Preview software provided (JNOPTIC Capture)
  • Software compatible with Windows XP/ Vista/ 7/ 8 operating systems

LIVE PSEUDO COLOR

Ex. of applied PSEUDO COLOR for black live fluorescence image

Emphasis function on variety of images

AcquCAM Pro G3_15
With emphasis function, BLACK BALANCE / AUTO LEVEL of ARM on variety images, you could acquire cleaner and sharper images.

Acquiring high sensitive images

These images were shot by AcquCAM Silver Package.

Acquiring high sensitive images from general lighting source

[Specification]

SpecDescription
Size1/3 inch
ResolutionH: 1280, V: 960
Pixel sizeH: 3.75 µm, V: 3.75 µm
Video formats   & Frame rate1280×960 RGB32 @ 30, 20, 15, 7.5, 3.75 fps   1280×960 Y800 @ 30, 20, 15, 7.5, 3.75 fps 1280×960 Y16 @ 30, 20, 15, 7.5, 3.75 fps
Sensitivity0.05 lx
Exposure time1/10000 to 30 s
Lens mountC/Cs mount
InterfaceUSB 3.0
Power supply4.5 to 5.5 VDC
DimensionsH: 29 mm, W: 29 mm, L: 43 mm
Mass65 g

AcquCAM 23S2

AcquCAM 23S2

가시광선 & 근적외선(NIR) 관찰

CA3 pyramidal neuron IR-DIC Camera : AcquCAM 23S2
CA3 pyramidal neuron, IR-DIC & Alexa Fluo 488 at the same time
Figure courtesy by Dr. Sooyun Kim, Seoul National University
with Bx51WI, JNO-DPTS, AcquCAM 23S
JNO-DPTS
JNO-DPTS CA3 pyramidal neuron, IR-DIC & Alexa Fluo 488 at the same time Figure courtesy by Dr. Sooyun Kim, Seoul National University with Bx51WI, JNO-DPTS, AcquCAM 23S
  • USB 3.0 Monochrome Camera
  • 1/1.2 ” Pregius Sensor
  • 1920×1200 pixel
  • Trigger input and I/O
  • Cost-effective mono camera for fluorescence microscope (Best)
  • Cost-effective camera for Department of Physiology (Best)
  • 1/1.2 inch optimized sensor size for microscope field of view
  • Acquire images of optimum width combined with 0.63x adapter
Microscopy Camera
AcquCAM 23S2

AcquCAM 23S2 mono camera has a USB 3.0 interface and is the perfect solution for many industrial automation, quality assurance, security, surveillance and medical applications. The mono camera ships with the very sensitive 1/1.2 inch CMOS Pregius  sensor. With up to 162 images per second, the AcuqCAM 23S2 is a low cost, yet highly versatile imaging solution. The camera includes a C to CS mount adapter, making it compatible to C and CS mount lenses.

Images with AcquCAM 23S2
AcquCAM 23S2 Fluorescence camera DAPI, FITC, TRITC
Sample : bovine pulmonary artery endothelial cell, BPAEC Filter Set : JNO-U(B), B(B), G(B) Camera : AcquCAM 23S2 C-mount adapter : 1x Lens : UPlanAPO 40x Above three images are merged and processed using ARM S/W
AcquCAM 23S2 Fluorescence camera DAPI, FITC, TRITC
Sample : bovine pulmonary artery endothelial cell, BPAEC Filter Set : JNO-U(B), B(B), G(B) Camera : AcquCAM 23S2 C-mount adapter : 1x Lens : UPlanAPO 40x Above three images are merged and processed using ARM S/W

Specification

SpecDescription
  Size  1/1.2 inch
  Resolution  H: 1920, V: 1200
 Pixel size  H: 5.86 µm, V: 5.86 µm
 Video formats & Frame rate1920×1200  Y16    @    80 fps
1920×1200  Y800 @ 162 fps
  Sensitivity  0.015 lx
  Exposure time  20㎲ to 30 s
  Lens mount  C/Cs mount
  Interface  USB 3.0
  Power supply  4.5 to 5.5 VDC
  Dimensions  H: 29 mm, W: 29 mm, L: 43 mm
  Mass  65 g

AcquCAM 카메라 현미경 관찰법 대응표

AcquCAM 카메라 스펙 비교표

Setup Driver & Software Download

AcquCAM 3G

AcquCAM 3G

  • USB 3.0 Color Camera
  • 1/1.8 ” Pregius Sensor
  • 2048 x 1536 pixel
  • Trigger input and I/O
  • Cost-effective color camera
  • High Sensitivity Sensor
  • Fast, seamless image transfer
  • Available of images with a very wide field of view
  • Low Noise Sensor
AcquCAM 3G
AcquCAM 3G

AcquCAM 3G color camera has a USB 3.0 interface and is the perfect solution for many industrial automation, quality assurance, security, surveillance and medical applications. The color camera ships with the very sensitive 1/1.8 inch CMOS Pregius  sensor. With up to 60 images per second, the AcuqCAM 3G is a low cost, yet highly versatile imaging solution. The camera includes a C to CS mount adapter, making it compatible to C and CS mount lenses. Using the optional CS to M12 board lens adapter, the camera is
also compatible to M12 board lenses.

Images with AcquCAM 3G

Sample : bovine pulmonary artery endothelial cell, BPAEC Camera : AcquCAM 3G, Filter Set : JNO-U(B),B(B),G(B) Objective lens : UPLNAPO40X, C-mount adapter : 1X Above three images are merged and processed using JNO-ARM
Sample : bovine pulmonary artery endothelial cell, BPAEC Camera : AcquCAM 3G, Filter Set : JNO-U(B),B(B),G(B) Objective lens : UPLNAPO40X, C-mount adapter : 1X Above three images are merged and processed using JNO-ARM

Specification

SpecDescription
Size1/1.8 inch
ResolutionH: 2048, V: 1536
Pixel sizeH: 3.45 µm, V: 3.45 µm
Video formats& Frame rate2048×1536 (3.1 MP) RGB64 @ 60 fps   2048×1536 (3.1 MP) RGB32 @ 60 fps
2048×1536 (3.1 MP) Y16 @ 60 fps 2048×1536 (3.1 MP) Y411 @ 60 fps
2048×1536 (3.1 MP) YUY2 @ 60 fps
Dynamic range8 / 12 bit
Exposure time20 ㎲ to 30s
Lens mountC/Cs mount
InterfaceUSB 3.0
Power supply4.5 to 5.5 VDC
DimensionsH: 29 mm, W: 29 mm, L: 43 mm
Mass65g

AcquCAM 카메라 현미경 관찰법 대응표

AcquCAM 카메라 스펙 비교표

Setup Driver & Software Download

LIGHT SOURCE FOR FLUORESCENCE MICROSCOPE

CoolLED pE-300lite

  • 수명 :  25,000시간
  • UV (DAPI) ~ Red (Cy5 EX) 의 스펙트럼
  • 무수은 대체 장치
  • 1 % 단위의 정밀한 밝기 제어 (0-100 %)

CoolLED pE-300whtie

  • 수명 :  25,000시간
  • UV (DAPI) ~ Red (Cy5 EX) 의 스펙트럼
  • 무수은 대체 장치
  • 1 % 단위의 정밀한 밝기 제어 (0-100 %)
  • RGB 3채널 밝기 개별 제어
  • TTL & USB Control

CoolLED pE-300ultra

  • 수명 :  25,000시간
  • 파장 강도 및 셔터를 정밀하게 제어 가능
  • 다중 TTL 입력
  • 필터큐브 변경 없음
  • Sequence runner

CoolLED pE-340fura

  • 수명 :  25,000시간
  • Mercury-free
  • Energy Efficient: 80% less power
  • 빠른 리모트 컨트롤
  • Sequence runner

CoolLED pE-4000

  • 수명 :  25,000시간
  • 365~770nm 파장대
  • Instant on/off – no shutters
  • TTL & USB interfaces
  • Mercury-free & Laser-free
  • 수은 램프 교체 주기 :  평균 2,000시간
  • Powerful 130 W burner with long life time
  • Stable and uniform light output

U-LH100HG

  • 수은 램프 교체 주기 :   대략 200시간
  • 100 W Mercury Light Source
  • Entry-level fluorescence excitation light source
  • Applicable for all common fluorophores

U-LH75XEAPO

  • 제논 램프 교체 주기 :   대략 200시간
  • 75 W xenon burner
  • Ideally suited for far-red and IR excitation
  • Highly corrected for optical

U-LH50HG

  • 수은 램프 교체 주기 :   대략 200시간
  • 50 W Mercury Light Source
  • Entry-level fluorescence excitation light source
  • Applicable for all common

FISH

Fluorescence In Situ Hybridization
– 형광동소보합법 –

Many factors influence the quality of FISH

1. Processing & storage2. Specimen3. Probes
4. Microscope5. Filters6. Light source
Many factors influence the quality of FISH
필터 선정시 고려 할 사항설 명
ContrastSignal / Noise ratio =
MORE CONTRAST
BrightnessSave time, increase throughput
and reduce eye strain with brighter images
Color SeparationDistinguish between colors
more easily and exclude unwanted colors
RegistrationEach filter set produces images that are aligned with images from other filter sets
형광 필터 선정시 고려할 포인트

Spectrum chart

이미지의 상단을 클릭하시면 원본 스펙트럼 차트를 보실 수 있습니다.

Fluorescent Samples

판매용 형광 샘플

Fluorescent Samples for Sale

이미지 상단부분을 클릭하시면 원본 이미지를 확인하실 수 있습니다.

형광샘플 촬영 조건

  • 4ch 크로마 형광 필터
  • Camera: AcquCAM 23GR2
  • Objetives: UPlanApo40x
  • Camera Adapter: 1x
  • Light source: CoolLED pE-300ultra

Fluorophores

Browse By Fluorochrome

Compare filter sets by selecting the recommended/alternative set listed for each fluorochrome below.

  • If you need more information, please click fluorochrome. You can see each fluorochrome information and recommended filter sets.
  • If you need other dye information, please contact us.
  • Tel : 02-3473-4188~9
  • E-mail : jhjin@jnoptic.com

하단의 Fluorochrome 이름을 클릭하시면
대응되는 형광필터의 조합을 확인 하실 수 있습니다.

AlexaFluor 594

Alexa Fluor 594 dye is a bright, red-fluorescent dye that can be excited using the 561 nm or 594 nm laser lines. For stable signal generation in imaging and flow cytometry, Alexa Fluor 594 dye is pH-insensitive over a wide molar range.

Spectrum-Chart_Alexa-Fluor-594
Spectrum-Chart_Alexa-Fluor-594

CFP

Cyan Fluorescent Protein (CFP) is a versatile biological marker for monitoring physiological processes, visualizing protein localization, and detecting transgenic expression in vivo. CFP can be excited by the 405 nm laser line and is optimally detected at 485 nm.

Spectrum-Chart_CFP
Spectrum-Chart_CFP

Cy5

Cy5 dye is a bright, far-red-fluorescent dye that can be excited using the 633 or 647 nm laser lines, and visualized Cy5 filter sets.  In addition to immunocytochemistry applications, Cy5 is also commonly used to label nucleic acids.

Spectrum-Chart_Cy5
Spectrum-Chart_Cy5

Cy5.5

A variety of cyanine 5.5 (Cy5.5) dyes has been used to label biological molecules for fluorescence imaging and other fluorescence-based biochemical analysis. They are widely used for labeling peptides, proteins and oligos etc. Cy5.5 dyes are one type of the most common red fluorophores.

Spectrum-Chart_Cy5.5
Spectrum-Chart_Cy5.5

Cy7

Cy7 is a near-IR fluor that is invisible to the naked eye (Excitation/emission maximum 750/776 nm). It is used in in vivo imaging applications, as well as the Cy7.5 dye.

Spectrum-Chart_Cy7
Spectrum-Chart_Cy7

DAPI

DAPI (4′,6-diamidino-2-phenylindole) is a fluorescent stain that binds strongly to A-T rich regions in DNA. It is used extensively in fluorescence microscopy. As DAPI can pass through an intact cell membrane, it can be used to stain both live and fixed cells, though it passes through the membrane less efficiently in live cells and therefore the effectiveness of the stain is lower.

Spectrum-Chart_DAPI
Spectrum-Chart_DAPI

FITC

Fluorescein isothiocyanate (FITC) is a derivative of fluorescein used in wide-ranging applications including flow cytometry. FITC is the original fluoresce in molecule functionalized with an isothiocyanate reactive group (-N=C=S), replacing a hydrogen atom on the bottom ring of the structure. This derivative is reactive towards nucleophiles including amine and sulfhydryl groups on proteins.

Spectrum-Chart_FITC
Spectrum-Chart_FITC

GFP

The green fluorescent protein (GFP) is a protein composed of 238 amino acid residues (26.9 kDa) that exhibits bright green fluorescence when exposed to light in the blue to ultraviolet range. Although many other marine organisms have similar green fluorescent proteins, GFP traditionally refers to the protein first isolated from the jellyfish Aequorea victoria. The GFP from A. victoria has a major excitation peak at a wavelength of 395 nm and a minor one at 475 nm. Its emission peak is at 509 nm, which is in the lower green portion of the visible spectrum.

Spectrum-Chart_GFP
Spectrum-Chart_GFP

tdTomato

tdTomato is a genetic fusion of two copies of the dTomato gene (2) which was specifi cally designed for low aggregation (1). Its tandem dimer structure plays an important role in the exceptional brightness of tdTomato (Table I). Its excitation and emission maxima occur at 554 nm and 581 nm, respectively (1). Because tdTomato forms an intramolecular dimer, it behaves like a monomer, and has been used successfully for N- and C- terminal fusions. It shows excellent photostability and its half-time (t0.5) for maturation is one hour at 37°C.

TRITC

Tetramethylrhodamine (TRITC) is a bright orange-fluorescent dye with excitation ideally suited to the 532 nm laser line. It is commonly conjugated to antibodies and proteins for cellular imaging applications.

Spectrum-Chart_TRITC
Spectrum-Chart_TRITC

light source for Fluorescence

형광 관찰 조명장치의 종류

  • Mercury : 형광 현미경법에 가장 흔히 사용하는 광원으로, 자외선 및 가시광선 영역에서 아주 밝다.
Spectrum of mercury
  • Xenon : 가시광선에서 상대적으로 연속적인 스펙트럼을 가진다. 염료 및/또는 시료의 스펙트럼 특성을 정량적으로 분석하는 시스템에서는 제논 램프를 사용하는 것이 좋지만, 같은 와트수의 수은 램프만큼 밝지는 않다.
Spectrum of Xenon
  • LED :  약 10 ~ 40nm 범위의 상대적으로 좁은 스펙트럼 대역폭 내에서 빛을 방출한다는 고유의 특징이 있다. 일반적으로 정격 수명이 10,000시간 이상이고 50,000시간 이상 사용하는 경우도 많고, 전체 정격 수명에 걸쳐 출력 강도가 비교적 일정하게 유지된다.
Spectrum of LED

Laser : 레이저

  • 보통은 단색광의 좁은 스펙트럼 대역에서 극히 밝다. 하지만 레이저광의 간섭성으로 인해 샘플 영역에 균일한 조도로 비추기 어렵지만, Confocal 현미경에서는 갈바노 미러를 이용한 스캔 방식을 이용하여 이미지 획득시에 사용되어진다(LSCM).
    Spectrum of Laser

Metal-halide : 

  • 유효수명이 최대 2000시간으로, 일반적인 수은 램프의 200시간이나 제논 램프의 400시간과 비교하면 훨씬 길다.